About

Description

Auto Fire Extinguishing System

The Auto Fire Extinguishing System is designed to enhance fire safety during laser operations. Seamlessly integrated into the safety logic of compatible Bambu Lab machines, it works together with the AI camera and flame sensors to detect fire incidents and automatically inject CO2 gas into the chamber. The system also includes a manual emergency mechanism that can be used during a power outage.

Bambu Auto Fire Extinguishing System

Seamless Integration: Fully Automated Fire Extinguishing

The Auto Fire Extinguishing System is seamlessly integrated into the R1 and H2 series’ comprehensive safety behavior logic. It leverages the AI camera and flame sensors embedded in the machine to detect fire incidents and quickly react by injecting CO2 gas into the chamber, ensuring fully automatic fire suppression.

Fire detection system
CO2 automatic fire suppression

Manual Safety Mechanism: Your Backup in a Power Loss

A dedicated manual safety mechanism provides a critical backup. In the event of a power loss, an emergency manual trigger is available to activate the extinguisher, even when there’s no electricity to the system.

Auto Fire Extinguishing System emergency trigger

Installation Guide

For installation, please refer to the Auto Fire Extinguishing System installation guide on the Bambu Lab Wiki for the H2 Series and R1.

Important Notice Before Purchase

  • For your safety, it is essential to follow all safety protocols and never leave the printer during a laser job. The extinguisher does not guarantee a 100% success rate.
  • Compatible printers include H2D, H2D Pro, H2S, H2C, and R1.
  • The gas cylinder is a one-time consumable and cannot be refilled after use.
  • A damaged or dented gas cylinder should not be used.

Product Specifications

Materials Plastic, Metal Packaging Size 385 × 218 × 130 mm
Color Gray, Black Packaging Weight 1.35 kg

Frequently Asked Questions

What printers is the extinguisher compatible with?

The extinguisher is compatible with H2D, H2D Pro, H2S, H2C and R1.

What firmware versions are required?

H2D: O1.02.00.00 or later.
H2D Pro: U1 01.01.00.00 or later.
H2S: 01.01.00.00 or later.
H2C: U1 01.01.00.00 or later.
Bambu Suite: 01.01.01.50 or later.

Does the extinguisher guarantee a 100% success rate when a fire happens?

No. Always follow all safety protocols and do not leave the printer unattended while a laser task is in progress.

Why should the extinguisher be connected to an independent power source?

This helps ensure that the extinguisher can continue to function during an unexpected power outage if the printer loses power.

Can I refill a used gas cylinder?

No. The gas cylinder is a one-time consumable and must be replaced after use.

What type of gas cylinder works with the extinguisher?

Thread type: TR21X4
Volume: 0.6 L
Diameter: 60 mm
Length: ≤ 360 mm
Working pressure: 15 MPa

Can a dented gas cylinder still be used?

No. Do not use a gas cylinder if it is damaged, as this may compromise its function.

How can the extinguisher be activated during a power outage?

Use the emergency manual trigger to activate the extinguisher during a power outage.

Description

Auto Fire Extinguishing System

The Auto Fire Extinguishing System is designed to enhance fire safety during laser operations. Seamlessly integrated into the safety logic of compatible Bambu Lab machines, it works together with the AI camera and flame sensors to detect fire incidents and automatically inject CO2 gas into the chamber. The system also includes a manual emergency mechanism that can be used during a power outage.

Bambu Auto Fire Extinguishing System

Seamless Integration: Fully Automated Fire Extinguishing

The Auto Fire Extinguishing System is seamlessly integrated into the R1 and H2 series’ comprehensive safety behavior logic. It leverages the AI camera and flame sensors embedded in the machine to detect fire incidents and quickly react by injecting CO2 gas into the chamber, ensuring fully automatic fire suppression.

Fire detection system
CO2 automatic fire suppression

Manual Safety Mechanism: Your Backup in a Power Loss

A dedicated manual safety mechanism provides a critical backup. In the event of a power loss, an emergency manual trigger is available to activate the extinguisher, even when there’s no electricity to the system.

Auto Fire Extinguishing System emergency trigger

Installation Guide

For installation, please refer to the Auto Fire Extinguishing System installation guide on the Bambu Lab Wiki for the H2 Series and R1.

Important Notice Before Purchase

  • For your safety, it is essential to follow all safety protocols and never leave the printer during a laser job. The extinguisher does not guarantee a 100% success rate.
  • Compatible printers include H2D, H2D Pro, H2S, H2C, and R1.
  • The gas cylinder is a one-time consumable and cannot be refilled after use.
  • A damaged or dented gas cylinder should not be used.

Product Specifications

Materials Plastic, Metal Packaging Size 385 × 218 × 130 mm
Color Gray, Black Packaging Weight 1.35 kg

Frequently Asked Questions

What printers is the extinguisher compatible with?

The extinguisher is compatible with H2D, H2D Pro, H2S, H2C and R1.

What firmware versions are required?

H2D: O1.02.00.00 or later.
H2D Pro: U1 01.01.00.00 or later.
H2S: 01.01.00.00 or later.
H2C: U1 01.01.00.00 or later.
Bambu Suite: 01.01.01.50 or later.

Does the extinguisher guarantee a 100% success rate when a fire happens?

No. Always follow all safety protocols and do not leave the printer unattended while a laser task is in progress.

Why should the extinguisher be connected to an independent power source?

This helps ensure that the extinguisher can continue to function during an unexpected power outage if the printer loses power.

Can I refill a used gas cylinder?

No. The gas cylinder is a one-time consumable and must be replaced after use.

What type of gas cylinder works with the extinguisher?

Thread type: TR21X4
Volume: 0.6 L
Diameter: 60 mm
Length: ≤ 360 mm
Working pressure: 15 MPa

Can a dented gas cylinder still be used?

No. Do not use a gas cylinder if it is damaged, as this may compromise its function.

How can the extinguisher be activated during a power outage?

Use the emergency manual trigger to activate the extinguisher during a power outage.

Bambu Lab by Bambu Lab

Bambu Lab Gas Cylinder for R1 Laser

SKU: SL005-EU
Regular price
$49.99
Sale price
$49.99
Regular price
Shipping calculated at checkout.
Providing the best new Tech Experience, Energy Independence and Robotics Ways of Optimisation
Providing the best new Tech Experience, Energy Independence and Robotics Ways of Optimisation
Packaging note:
Equipment is being supplied in a manufacturer packaging

Check Out These Related Products